Model: Power LED Flood Lights
Power 10W-80W
Lumens 800lm-6400lm
Working Voltage 100-240VAC
Life Span >50,000 Hours
Base N/A
Certificates CE, RoHS, (UL Pending)
Warranty 24 Months
Download  Spec
Main Specifications: Chat with Eneltec using:

Model Number

Power LED Flood Lights

LED

Power LED

Color

Cool White/Warm White

CRI

>80

Luminescence Angle

50°/80°/100°/120°

Lumens

800lm-6400lm

Working Voltage

100-240VAC

Power Consumption

10W-80W

Lamp Base

N/A

Certification

CE, RoHS, (UL Pending)

Dimension

N/A

Packing

N/A

Special Features:
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Pictures The Model No. of this LED Flood Light is ENFL-10W-02 The Model No. of this LED Flood Light is ENFL-50W-02 The Model No. of this LED Flood Light is ENFL-80W-02
Model No. ENFL-10W-02 ENFL-10W-02PIR ENFL-20W-02 ENFL-20W-02PIR ENFL-30W-02 ENFL-30W-02PIR ENFL-40W-02 ENFL-40W-02PIR ENFL-50W-02 ENFL-50W-02PIR ENFL-60W-02 ENFL-60W-02PIR ENFL-70W-02 ENFL-70W-02PIR ENFL-80W-02 ENFL-80W-02PIR
Power
Consumption
(W)
10 10 20 20 30 30 40 40 50 50 60 60 70 70 80 80
LED Initial
Flux
(LM) 
800 800 1600 1600 2400 2400 3200 3200 4000 4000 4800 4800 5600 5600 6400 6400
Lamp
Flux
(LM) 
700 700 1400 1400 2100 2100 2800 2800 3500 3500 4200 4200 4900 4900 5600 5600
Beam
Angle
50°/120° 50°/120° 50°/100° 50°/100° 50°/100° 50°/100° 50°/100° 50°/100° 50°/100° 50°/100° 50°/80° 50°/80° 50°/80° 50°/80° 50°/80° 50°/80°
Input
Voltage
100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC
PF >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97 >0.97
Power Efficiency 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87% 87%
Color Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
Warm White
Cool White
CRI Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80 Ra>80
Working
Enviornment
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Temperature: -25℃~45℃
Humidity: 10%~90%
Material Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy Aluminum Alloy
IP
Rating
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
IP65 Lamp:IP65
PIR:IP44
Working
Life
(Hours)
>50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000 >50000
Product
Dimension
(mm)
115×86×105 115×86×105 225×185×126 225×185×126 225×185×126 225×185×126 290×236×150 290×236×150 290×236×150 290×236×150 360×285×110 360×285×110 360×285×110 360×285×110 360×285×110 360×285×110
Packing
Dimension
(mm)
Lamp:20 pcs
537×292×269
PIR:20 pcs
130×100×170
Lamp:4 pcs
574×360×289
PIR:20 pcs
130×100×170
Lamp:4 pcs
574×360×289
PIR:20 pcs
130×100×170
Lamp:4 pcs
674×404×329
PIR:20 pcs
130×100×170
Lamp:4 pcs
674×404×329
PIR:20 pcs
130×100×170
Lamp:2 pcs
487×340×388
PIR:20 pcs
130×100×170
Lamp:2 pcs
487×340×388
PIR:20 pcs
130×100×170
Lamp:2 pcs
487×340×388
PIR:20 pcs
130×100×170
Net Weight/ Gross Weight (Kgs)
Lamp:20 pcs
14.4/16.0
PIR:20 pcs
9.5/10.5
Lamp:4 pcs
11.3/12.5
PIR:20 pcs
9.5/10.5
Lamp:4 pcs
11.3/12.5
PIR:20 pcs
9.5/10.5
Lamp:4 pcs
17.1/19.0
PIR:20 pcs
9.5/10.5
Lamp:4 pcs
17.1/19.0
PIR:20 pcs
9.5/10.5
Lamp:2 pcs
13.5/15.0
PIR:20 pcs
9.5/10.5
Lamp:2 pcs
13.5/15.0
PIR:20 pcs
9.5/10.5
Lamp:2 pcs
13.5/15.0
PIR:20 pcs
9.5/10.5

 

.Saving electricity up to 50% compared to Flood Light 
.Safety enhancement with glass-material
.Eco-friendly .No mercury contained
.Anti-global warming by reduction of CO2 emission
.Low temperature maintained by unique heat dissipation mechanism
.Longer Lifetime of 30000~50000 hrs
.Warranty period is 2 years from the date of purchase(Om condition
that operating ambient temperature is 0°C~30°C (32°F~86°F) and use time is hours per day)

 

 

Application:

Widely used in the hotel, meeting room, offices , hospital , schools , factories , commercial lighting , shopping malls, supermarkets, kitchen, diaplay, backlight and so on. 

Comparison of Lifetime:

 

Flood Light

 6000,hours lifetime  Increase the
replacement cost
   LED Flood Light  50000,hours lifetime  long time with
2 years warranty

Product Dimension

Power LED Flood Lights Product Dimension 10W

10W

Power LED Flood Lights Product Dimension 20W 30W

20W 30W

Power LED Flood Lights Product Dimension 40W 50W

40W 50W

Power LED Flood Lights Product Dimension 60W 80W

60W 80W

Photomatric Data

Photomatric Data of 50° Power LED Flood Lights

Photomatric Data of 80° 100° Power LED Flood Lights

Photomatric Data of 120° Power LED Flood Lights

Packing

Packing of Power LED Flood Lights

Installation Methods

Installation Methods of Power LED Flood Lights:Sitting Installation, Wall-hung Installation, Ceiling Installation

Installation Steps

Installation Steps of Power LED Flood Lights

 

first lamps fixed in the bracket, adjust the illumination angle, and then the
metal bracket fixed nut tighten

 

 

As shown in Figure 1 installation of sensors, the two plugs are fixed on the mounting surface; the fixed AB screws sensors mounted in a highly position as shown in Figure 2; as shown in Figure 3, with waterproof male and female on wiring, connected with the lamp body and the inductor is connected, tighten

 

The correct installation: knob face-down, faces the sensing direction

 

As Picture showed, Connect Live Wrire/Null Wire/Ground Wire to electric cable properly and switch on.

1. As shown, the first metal bracket nuts to loosen, the bracket removed, and three holes on the metal bracket fixed on the mounting surfaces.

2. As shown, in the first lamps fixed in the bracket, adjust the illumination angle, and then the metal bracket fixed nut tighten;

3. After the installation, to check all the major components are installed correctly in place, confirm the screws are tightening.

4. As shown in Figure 1 installation of sensors, the two plugs are fixed on the mounting surface; the fixed AB screws sensors mounted in a highly position as shown in Figure 2; as shown in Figure 3, with waterproof male and female on wiring, connected with the lamp body and the inductor is connected, tighten

5. The inductive probe knob does not allow upward. There are leakage hole on the adjusting knob, can avoid the stagnant water.

6. As Picture showed, Connect Live Wrire/Null Wire/Ground Wire to electric cable properly and switch on.

Debugging sensor status

Debugging sensor status of Power LED Flood Lights, Set the function button below the sensor. Shown in figure C; TIME – Lighting time setting, LUX – Environment brightness setting

1. Sensor angle can be adjusted up and down to set different induction range. Shown in figure A and figure B

2. Set the function button below the sensor. Shown in figure C; TIME – Lighting time setting, LUX – Environment brightness setting

3. Set the TIME in 5 seconds and the LUX in the daytime position, then can be inductive range test mold

4. Turn on the power, then the lamps will be in the status of warming up the machine, people need to leave the sensing area, probably the lamp will light 1-2 minutes, then automatically turn off

5. Turn on the power, then the lamps will be in the status of warming up the machine, people need to leave the sensing area, probably the lamp will light 1-2 minutes, then automatically turn off

Sensor automatic inductive setting

.1. When the above installation debugging completed, the lamps need to be set for automatic sensor lighting mode

1. When adjust the lighting, transferred the adjustable twist from [5 seconds] slowly clockwise rotation Enter into the sensor detection range, after confirm the lights turn on, please leave immediately (if the person remain within the sensing range, it will result in the lighting time extended)

2. Change the light adjustable twist from [day] rotate clockwise to do [day and night lighting, dusk began lighting or only night lighting ] function setting The installation should be in actual position environment setting

For the sensor cross-section occasions, the sensor sensitivity is high. For the sensor straight forward occasions, sensor sensitivity becomes relatively low. As shown in figure D

Installation notice

1. Please strictly follow the installation steps, the non-professional electrician does not allow any operation.

2. Please make sure the hanging system of the lamp installation must be capable of carrying the floodlights overall more than 25Kg in order to be safe

3. Make sure the supply voltage range can not exceed AC100-240V 50/60Hz this range, it will lead to the result of lamps does not light up or burn lights

4. Due to the sensor detects the ambient brightness and temperature changes, in the following installation site, sometimes caused by the misuse detection or non-detection:

Do not close to the plants or curtain shaking by wind

Do not close to the air conditioning vents

Avoid the marble floors or walls strong reflection position

Avoid close to the glass partition wall

Do not installed in place easy to shake

Do not face to the road

Avoid the radio wave

Do not install in height above 4m

 

Maintenance

1. After a long time use, the lamp surface will attach some dust and other debris, which will directly affect the heat dissipation and glow of the lamps, so need for regular maintenance of the lamps, the general maintenance cycle is 8 to 12 months.

2. Maintenance focus on check each component of lamps in good condition, no loose screws and other anomalies, if any loosening (after good protection measures)

3. If the lamp shell surface are subject to dust and other debris, it need tools to clear, with particular attention to keep the lens surface clean. If there are debris, please try not to use corrosive and volatile liquid cleaning agent in order to avoid the lens surface scratches and chemical reactions, which will effect the luminous intensity and lighting of the lens, it is recommended to use fresh water or special cleaning agent.

4. If the LED lamp is not lit or flashing, the lens appear crack damaged, and you don't have the ability to replace it. Please contact directly with the supplier to deal with it.