Contact us
Rm 502, No.1090, Pingliang Rd, Shanghai, China, 200090
86-21-33811921, 33811922
86-21-33811923
Power LED Flood Lights
As the request and feedback from our customers, Eneltec now are posting new Power LED Flood Lights. These new series are from 10W-80W, for the Auxiliary lighting of the flood light application. Another new function is that the beam angle of these Power LED Flood Lights could be 50°/80°/100°/120°
![]() |
||
| Model: | Power LED Flood Lights | |
| Power | 10W-80W | |
| Lumens | 800lm-6400lm | |
| Working Voltage | 100-240VAC | |
| Life Span | >50,000 Hours | |
| Base | N/A | |
| Certificates | CE, RoHS, (UL Pending) | |
| Warranty | 24 Months | |
Model Number |
Power LED Flood Lights |
LED |
Power LED |
Color |
Cool White/Warm White |
CRI |
>80 |
Luminescence Angle |
50°/80°/100°/120° |
Lumens |
800lm-6400lm |
Working Voltage |
100-240VAC |
Power Consumption |
10W-80W |
Lamp Base |
N/A |
Certification |
CE, RoHS, (UL Pending) |
Dimension |
N/A |
Packing |
N/A |
| No. | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
| Pictures |
![]() |
![]() |
![]() |
|||||||||||||
| Model No. | ENFL-10W-02 | ENFL-10W-02PIR | ENFL-20W-02 | ENFL-20W-02PIR | ENFL-30W-02 | ENFL-30W-02PIR | ENFL-40W-02 | ENFL-40W-02PIR | ENFL-50W-02 | ENFL-50W-02PIR | ENFL-60W-02 | ENFL-60W-02PIR | ENFL-70W-02 | ENFL-70W-02PIR | ENFL-80W-02 | ENFL-80W-02PIR |
|
Power Consumption (W) |
10 | 10 | 20 | 20 | 30 | 30 | 40 | 40 | 50 | 50 | 60 | 60 | 70 | 70 | 80 | 80 |
|
LED Initial Flux (LM) |
800 | 800 | 1600 | 1600 | 2400 | 2400 | 3200 | 3200 | 4000 | 4000 | 4800 | 4800 | 5600 | 5600 | 6400 | 6400 |
|
Lamp Flux (LM) |
700 | 700 | 1400 | 1400 | 2100 | 2100 | 2800 | 2800 | 3500 | 3500 | 4200 | 4200 | 4900 | 4900 | 5600 | 5600 |
|
Beam Angle |
50°/120° | 50°/120° | 50°/100° | 50°/100° | 50°/100° | 50°/100° | 50°/100° | 50°/100° | 50°/100° | 50°/100° | 50°/80° | 50°/80° | 50°/80° | 50°/80° | 50°/80° | 50°/80° |
|
Input Voltage |
100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC |
| PF | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 | >0.97 |
| Power Efficiency | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% | 87% |
| Color |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
Warm White Cool White |
| CRI | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 | Ra>80 |
|
Working Enviornment |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
Temperature: -25℃~45℃ Humidity: 10%~90% |
| Material | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy | Aluminum Alloy |
|
IP Rating |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
IP65 |
Lamp:IP65 PIR:IP44 |
|
Working Life (Hours) |
>50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 | >50000 |
|
Product Dimension (mm) |
115×86×105 | 115×86×105 | 225×185×126 | 225×185×126 | 225×185×126 | 225×185×126 | 290×236×150 | 290×236×150 | 290×236×150 | 290×236×150 | 360×285×110 | 360×285×110 | 360×285×110 | 360×285×110 | 360×285×110 | 360×285×110 |
|
Packing Dimension (mm) |
Lamp:20 pcs 537×292×269 PIR:20 pcs 130×100×170 |
Lamp:4 pcs 574×360×289 PIR:20 pcs 130×100×170 |
Lamp:4 pcs 574×360×289 PIR:20 pcs 130×100×170 |
Lamp:4 pcs 674×404×329 PIR:20 pcs 130×100×170 |
Lamp:4 pcs 674×404×329 PIR:20 pcs 130×100×170 |
Lamp:2 pcs 487×340×388 PIR:20 pcs 130×100×170 |
Lamp:2 pcs 487×340×388 PIR:20 pcs 130×100×170 |
Lamp:2 pcs 487×340×388 PIR:20 pcs 130×100×170 |
||||||||
| Net Weight/ Gross Weight (Kgs) |
Lamp:20 pcs 14.4/16.0 PIR:20 pcs 9.5/10.5 |
Lamp:4 pcs 11.3/12.5 PIR:20 pcs 9.5/10.5 |
Lamp:4 pcs 11.3/12.5 PIR:20 pcs 9.5/10.5 |
Lamp:4 pcs 17.1/19.0 PIR:20 pcs 9.5/10.5 |
Lamp:4 pcs 17.1/19.0 PIR:20 pcs 9.5/10.5 |
Lamp:2 pcs 13.5/15.0 PIR:20 pcs 9.5/10.5 |
Lamp:2 pcs 13.5/15.0 PIR:20 pcs 9.5/10.5 |
Lamp:2 pcs 13.5/15.0 PIR:20 pcs 9.5/10.5 |
||||||||
.Eco-friendly .No mercury contained
.Anti-global warming by reduction of CO2 emission
.Low temperature maintained by unique heat dissipation mechanism
.Longer Lifetime of 30000~50000 hrs
.Warranty period is 2 years from the date of purchase(Om condition
that operating ambient temperature is 0°C~30°C (32°F~86°F) and use time is hours per day)
Application:

Widely used in the hotel, meeting room, offices , hospital , schools , factories , commercial lighting , shopping malls, supermarkets, kitchen, diaplay, backlight and so on.

Comparison of Lifetime:
![]() |
Flood Light |
6000,hours lifetime |
Increase the replacement cost |
![]() |
LED Flood Light | 50000,hours lifetime |
long time with 2 years warranty |
Product Dimension
Photomatric Data



Packing

Installation Methods

Installation Steps



1. As shown, the first metal bracket nuts to loosen, the bracket removed, and three holes on the metal bracket fixed on the mounting surfaces.
2. As shown, in the first lamps fixed in the bracket, adjust the illumination angle, and then the metal bracket fixed nut tighten;
3. After the installation, to check all the major components are installed correctly in place, confirm the screws are tightening.
4. As shown in Figure 1 installation of sensors, the two plugs are fixed on the mounting surface; the fixed AB screws sensors mounted in a highly position as shown in Figure 2; as shown in Figure 3, with waterproof male and female on wiring, connected with the lamp body and the inductor is connected, tighten
5. The inductive probe knob does not allow upward. There are leakage hole on the adjusting knob, can avoid the stagnant water.
6. As Picture showed, Connect Live Wrire/Null Wire/Ground Wire to electric cable properly and switch on.
Debugging sensor status
1. Sensor angle can be adjusted up and down to set different induction range. Shown in figure A and figure B
2. Set the function button below the sensor. Shown in figure C; TIME – Lighting time setting, LUX – Environment brightness setting
3. Set the TIME in 5 seconds and the LUX in the daytime position, then can be inductive range test mold
4. Turn on the power, then the lamps will be in the status of warming up the machine, people need to leave the sensing area, probably the lamp will light 1-2 minutes, then automatically turn off
5. Turn on the power, then the lamps will be in the status of warming up the machine, people need to leave the sensing area, probably the lamp will light 1-2 minutes, then automatically turn off
Sensor automatic inductive setting
.1. When the above installation debugging completed, the lamps need to be set for automatic sensor lighting mode

1. When adjust the lighting, transferred the adjustable twist from [5 seconds] slowly clockwise rotation Enter into the sensor detection range, after confirm the lights turn on, please leave immediately (if the person remain within the sensing range, it will result in the lighting time extended)
2. Change the light adjustable twist from [day] rotate clockwise to do [day and night lighting, dusk began lighting or only night lighting ] function setting The installation should be in actual position environment setting
For the sensor cross-section occasions, the sensor sensitivity is high. For the sensor straight forward occasions, sensor sensitivity becomes relatively low. As shown in figure D
Installation notice
1. Please strictly follow the installation steps, the non-professional electrician does not allow any operation.
2. Please make sure the hanging system of the lamp installation must be capable of carrying the floodlights overall more than 25Kg in order to be safe
3. Make sure the supply voltage range can not exceed AC100-240V 50/60Hz this range, it will lead to the result of lamps does not light up or burn lights
4. Due to the sensor detects the ambient brightness and temperature changes, in the following installation site, sometimes caused by the misuse detection or non-detection:
Do not close to the plants or curtain shaking by wind
Do not close to the air conditioning vents
Avoid the marble floors or walls strong reflection position
Avoid close to the glass partition wall
Do not installed in place easy to shake
Do not face to the road
Avoid the radio wave
Do not install in height above 4m
Maintenance
1. After a long time use, the lamp surface will attach some dust and other debris, which will directly affect the heat dissipation and glow of the lamps, so need for regular maintenance of the lamps, the general maintenance cycle is 8 to 12 months.
2. Maintenance focus on check each component of lamps in good condition, no loose screws and other anomalies, if any loosening (after good protection measures)
3. If the lamp shell surface are subject to dust and other debris, it need tools to clear, with particular attention to keep the lens surface clean. If there are debris, please try not to use corrosive and volatile liquid cleaning agent in order to avoid the lens surface scratches and chemical reactions, which will effect the luminous intensity and lighting of the lens, it is recommended to use fresh water or special cleaning agent.
4. If the LED lamp is not lit or flashing, the lens appear crack damaged, and you don't have the ability to replace it. Please contact directly with the supplier to deal with it.